{"id":65,"date":"2009-03-05T10:25:45","date_gmt":"2009-03-05T10:25:45","guid":{"rendered":"http:\/\/ravtrack.com\/GPStracking\/?p=65"},"modified":"2010-06-17T04:07:06","modified_gmt":"2010-06-17T04:07:06","slug":"m7-firmware-updating","status":"publish","type":"post","link":"https:\/\/www.raveon.com\/data_radio_info\/m7-firmware-updating-65\/","title":{"rendered":"M7 Firmware Updating"},"content":{"rendered":"<div class=\"mceTemp\">\n<h1 class=\"mceTemp mceIEcenter\" style=\"text-align: left;\"><span style=\"font-size: large; color: #333399; font-family: Arial;\">Overview<\/span><\/h1>\n<\/div>\n<p class=\"MsoNormal\" style=\"margin: 0in 0in 6pt;\"><span style=\"font-size: small;\"><span style=\"font-family: Arial;\">This Technical Brief describes how to upload firmware into the <a title=\"data radio products\" href=\"http:\/\/www.raveontech.com\/Products.html\">RV-M7<\/a> transceiver. <span style=\"mso-spacerun: yes;\">\u00a0<\/span>The RV-M7 series transceivers utilize a Phillips ARM-based Microprocessor with internal FLASH memory.<span style=\"mso-spacerun: yes;\"> <\/span><\/span><\/span><\/p>\n<p class=\"MsoNormal\" style=\"margin: 0in 0in 6pt;\"><span style=\"font-size: small;\"><span style=\"font-family: Arial;\">All RV-M7-GX series transceiver use an LPC2136 processor, which has 256kB of flash memory.<span style=\"mso-spacerun: yes;\"> <\/span><\/span><\/span><\/p>\n<p class=\"MsoNormal\" style=\"margin: 0in 0in 6pt;\"><span style=\"font-size: small; font-family: Arial;\">Phillips Semiconductor provides a utility to upload firmware into the microprocessor. Their program is called \u201cLPC2000 Flash Utility\u201d This utility may be used in the field to upload new firmware into the RV-M7 series transceivers. <\/span><\/p>\n<p class=\"MsoNormal\" style=\"margin: 0in 0in 6pt;\"><span style=\"font-size: small; font-family: Arial;\">Firmware updating\u00a0information and software revision implications is also available in <a href=\"http:\/\/www.raveontech.com\/ApplicationNotes\/AN136-UploadingFlash.pdf\">Application Note\u00a0AN136<\/a>\u00a0which is\u00a0in .pdf form.<\/span>\u00a0<\/p>\n<div style=\"border-right: medium none; padding-right: 0in; border-top: medium none; padding-left: 0in; padding-bottom: 1pt; border-left: medium none; padding-top: 0in; border-bottom: windowtext 1pt solid; mso-border-bottom-alt: solid windowtext .5pt; mso-element: para-border-div;\">\n<h1 style=\"margin: 0in 0in 6pt;\"><span style=\"font-size: large; color: #333399; font-family: Arial;\"><em>Procedure<\/em><\/span><\/h1>\n<\/div>\n<h2 style=\"margin: 0in 0in 6pt;\"><em><span style=\"text-decoration: underline;\"><span style=\"font-size: small; font-family: Arial;\">1.0<span style=\"mso-tab-count: 1;\"> <\/span>Uploading Firmware<\/span><\/span><\/em><\/h2>\n<p class=\"MsoBodyText\" style=\"margin: 0in 0in 6pt 0.5in; text-indent: -0.25in; tab-stops: list .5in; mso-list: l1 level1 lfo1;\"><span style=\"mso-fareast-font-family: Arial; mso-bidi-font-family: Arial;\"><span style=\"mso-list: Ignore;\"><span style=\"font-size: small; font-family: Arial;\">1.<\/span><span style=\"font: 7pt &amp;amp;amp;\"> <\/span><\/span><\/span><span style=\"font-size: small; font-family: Arial;\">Extract the .zip files if the firmware update was supplied in .zip format.<\/span><\/p>\n<p class=\"MsoBodyText\" style=\"margin: 0in 0in 6pt 0.5in; text-indent: -0.25in; tab-stops: list .5in; mso-list: l1 level1 lfo1;\"><span style=\"mso-fareast-font-family: Arial; mso-bidi-font-family: Arial;\"><span style=\"mso-list: Ignore;\"><span style=\"font-size: small; font-family: Arial;\">2.<\/span><span style=\"font: 7pt &amp;amp;amp;\"> <\/span><\/span><\/span><span style=\"font-size: small; font-family: Arial;\">Open the Philips Flash Utility Installation.exe file inside the LPC21xx folder. The version must be V2.2.3 or higher.<span style=\"mso-spacerun: yes;\"> Version 2.2.3 is available <a href=\"http:\/\/ravtrack.com\/downloads\/Philips223.zip\">&lt;here&gt;<\/a>. <\/span>Walk through the installation steps to install the Philips Flash Utility program. The Utility program should open when the installation is complete. The Utility program window is shown below.<\/span><\/p>\n<p class=\"MsoBodyText\" style=\"margin: 0in 0in 6pt; text-align: center;\"><img loading=\"lazy\" class=\"size-full wp-image-32\" title=\"flashing\" src=\"http:\/\/www.raveontech.com\/data_radio_info\/wp-content\/uploads\/2009\/01\/flashing.jpg\" alt=\"Philips Flash Utility\" width=\"850\" height=\"404\" \/><\/p>\n<p class=\"MsoBodyText\" style=\"margin: 0in 0in 6pt 0.5in; text-indent: -0.25in; tab-stops: list .5in; mso-list: l1 level1 lfo1;\"><span style=\"mso-fareast-font-family: Arial; mso-bidi-font-family: Arial;\"><span style=\"mso-list: Ignore;\"><span style=\"font-size: small; font-family: Arial;\">3.<\/span><span style=\"font: 7pt &amp;amp;amp;\"> <\/span><\/span><\/span><span style=\"font-size: small; font-family: Arial;\">Select the appropriate COM port from the Connected To Port pull-down menu.<\/span><\/p>\n<p class=\"MsoBodyText\" style=\"margin: 0in 0in 6pt 0.5in; text-indent: -0.25in; tab-stops: list .5in; mso-list: l1 level1 lfo1;\"><span style=\"mso-fareast-font-family: Arial; mso-bidi-font-family: Arial;\"><span style=\"mso-list: Ignore;\"><span style=\"font-size: small; font-family: Arial;\">4.<\/span><span style=\"font: 7pt &amp;amp;amp;\"> <\/span><\/span><\/span><span style=\"font-size: small; font-family: Arial;\">Set the baud rate to 19200 from the Use Baud Rate pull-down menu.<\/span><\/p>\n<p class=\"MsoBodyText\" style=\"margin: 0in 0in 6pt 0.5in; text-indent: -0.25in; tab-stops: list .5in; mso-list: l1 level1 lfo1;\"><span style=\"mso-fareast-font-family: Arial; mso-bidi-font-family: Arial;\"><span style=\"mso-list: Ignore;\"><span style=\"font-size: small; font-family: Arial;\">5.<\/span><span style=\"font: 7pt &amp;amp;amp;\"> <\/span><\/span><\/span><span style=\"font-size: small; font-family: Arial;\">Set the XTAL Freq (kHz) to 20000.<\/span><\/p>\n<p class=\"MsoBodyText\" style=\"margin: 0in 0in 6pt 0.5in; text-indent: -0.25in; tab-stops: list .5in; mso-list: l1 level1 lfo1;\"><span style=\"mso-fareast-font-family: Arial; mso-bidi-font-family: Arial;\"><span style=\"mso-list: Ignore;\"><span style=\"font-size: small; font-family: Arial;\">6.<\/span><span style=\"font: 7pt &amp;amp;amp;\"> <\/span><\/span><\/span><span style=\"font-size: small; font-family: Arial;\">Select the appropriate file to upload to the modem. The file name will end in a .hex extension. <\/span><\/p>\n<p class=\"MsoBodyText\" style=\"margin: 0in 0in 6pt 0.5in; text-indent: -0.25in; tab-stops: list .5in; mso-list: l1 level1 lfo1;\"><span style=\"mso-fareast-font-family: Arial; mso-bidi-font-family: Arial;\"><span style=\"mso-list: Ignore;\"><span style=\"font-size: small; font-family: Arial;\">7.<\/span><span style=\"font: 7pt &amp;amp;amp;\"> <\/span><\/span><\/span><span style=\"font-size: small; font-family: Arial;\">Remove the four Phillips panhead screws securing the modem\u2019s rear panel to the housing. You don\u2019t need to disconnect the SMA GPS cable from the rear panel. <\/span><\/p>\n<p class=\"MsoBodyText\" style=\"margin: 0in 0in 6pt 0.5in; text-indent: -0.25in; tab-stops: list .5in; mso-list: l1 level1 lfo1;\"><span style=\"mso-fareast-font-family: Arial; mso-bidi-font-family: Arial;\"><span style=\"mso-list: Ignore;\"><span style=\"font-size: small; font-family: Arial;\">8.<\/span><span style=\"font: 7pt &amp;amp;amp;\"> <\/span><\/span><\/span><span style=\"font-size: small; font-family: Arial;\">Carefully remove the rear panel from the modem housing. The internal SMA GPS cable has a 2\u201d service loop to allow access to the modem\u2019s CONFIG button. The CONFIG button location is shown below.<\/span><\/p>\n<p class=\"MsoBodyText\" style=\"margin: 0in 0in 6pt; text-align: center;\"><span style=\"font-size: small; font-family: Arial;\"><img loading=\"lazy\" class=\"size-full wp-image-33 aligncenter\" title=\"configbutton\" src=\"http:\/\/www.raveontech.com\/data_radio_info\/wp-content\/uploads\/2009\/01\/configbutton.jpg\" alt=\"configbutton\" width=\"331\" height=\"212\" srcset=\"https:\/\/www.raveon.com\/data_radio_info\/wp-content\/uploads\/2009\/01\/configbutton.jpg 331w, https:\/\/www.raveon.com\/data_radio_info\/wp-content\/uploads\/2009\/01\/configbutton-300x192.jpg 300w\" sizes=\"(max-width: 331px) 100vw, 331px\" \/><\/span><\/p>\n<p class=\"MsoBodyText\" style=\"margin: 0in 0in 6pt; text-align: center;\">\n<p class=\"MsoBodyText\" style=\"margin: 0in 0in 6pt 0.5in; text-indent: -0.25in; tab-stops: list .5in; mso-list: l1 level1 lfo1;\"><span style=\"mso-fareast-font-family: Arial; mso-bidi-font-family: Arial;\"><span style=\"mso-list: Ignore;\"><span style=\"font-size: small; font-family: Arial;\">9.<\/span><span style=\"font: 7pt &amp;amp;amp;\"> <\/span><\/span><\/span><span style=\"font-size: small; font-family: Arial;\">Set a DC power supply for +12VDC. Set the power supply output OFF.<\/span><\/p>\n<p class=\"MsoBodyText\" style=\"margin: 0in 0in 6pt 0.5in; text-indent: -0.25in; tab-stops: list .5in; mso-list: l1 level1 lfo1;\"><span style=\"mso-fareast-font-family: Arial; mso-bidi-font-family: Arial;\"><span style=\"mso-list: Ignore;\"><span style=\"font-size: small; font-family: Arial;\">10.<\/span><span style=\"font: 7pt &amp;amp;amp;\"> <\/span><\/span><\/span><span style=\"font-size: small; font-family: Arial;\">Connect the PC serial port to the modem\u2019s DB9 front panel connector.<\/span><\/p>\n<p class=\"MsoBodyText\" style=\"margin: 0in 0in 6pt 0.5in; text-indent: -0.25in; tab-stops: list .5in; mso-list: l1 level1 lfo1;\"><span style=\"mso-fareast-font-family: Arial; mso-bidi-font-family: Arial;\"><span style=\"mso-list: Ignore;\"><span style=\"font-size: small; font-family: Arial;\">11.<\/span><span style=\"font: 7pt &amp;amp;amp;\"> <\/span><\/span><\/span><span style=\"font-size: small; font-family: Arial;\">Connect the modem\u2019s green 2-pin power connector to the power supply. <\/span><\/p>\n<p class=\"MsoBodyText\" style=\"margin: 0in 0in 6pt 0.5in; text-indent: -0.25in; tab-stops: list .5in; mso-list: l1 level1 lfo1;\"><span style=\"mso-fareast-font-family: Arial; mso-bidi-font-family: Arial;\"><span style=\"mso-list: Ignore;\"><span style=\"font-size: small; font-family: Arial;\">12.<\/span><span style=\"font: 7pt &amp;amp;amp;\"> <\/span><\/span><\/span><span style=\"font-size: small; font-family: Arial;\">Press and hold the modem CONFIG button. Set the power supply output to ON, wait approximately 2 seconds, and release the CONFIG button. If these steps were performed correctly the modem\u2019s current draw should be approximately 30mA.<\/span><\/p>\n<p class=\"MsoBodyText\" style=\"margin: 0in 0in 6pt 0.5in; text-indent: -0.25in; tab-stops: list .5in; mso-list: l1 level1 lfo1;\"><span style=\"mso-fareast-font-family: Arial; mso-bidi-font-family: Arial;\"><span style=\"mso-list: Ignore;\"><span style=\"font-size: small; font-family: Arial;\">13.<\/span><span style=\"font: 7pt &amp;amp;amp;\"> <\/span><\/span><\/span><span style=\"font-size: small; font-family: Arial;\">Press the Read Device ID button on the Philips Utility program window to establish communication with the modem. A reset message saying \u201cPlease reset your LPC2000 board now and then press OK!\u201d will appear. DO NOT RESET POWER TO THE MODEM. Press the OK button. A \u201cRead Part ID Successfully\u201d message will appear in the lower left corner of the Flash Utility program window.<\/span><\/p>\n<p class=\"MsoBodyText\" style=\"margin: 0in 0in 6pt 0.5in;\"><span style=\"font-size: small; font-family: Arial;\">Note: When the Read Device ID button is pressed the Utility program may display a \u201cCannot communicate with test board!\u201d message. Disregard this message. Press the OK button and press the Read Device ID button again to establish communications with the modem.<\/span><span style=\"font-size: small; font-family: Arial;\"> <\/span><\/p>\n<p class=\"MsoBodyText\" style=\"margin: 0in 0in 6pt 0.5in; text-indent: -0.25in; tab-stops: list .5in; mso-list: l1 level1 lfo1;\"><span style=\"mso-fareast-font-family: Arial; mso-bidi-font-family: Arial;\"><span style=\"mso-list: Ignore;\"><span style=\"font-size: small; font-family: Arial;\">14.<\/span><span style=\"font: 7pt &amp;amp;amp;\"> <\/span><\/span><\/span><span style=\"font-size: small; font-family: Arial;\">Press the Upload to Flash button on the Philips Utility program window to upload the 2F700GXB5.hex file to the modem\u2019s flash memory. The Utility program will display a \u201cFile Upload Successfully Completed\u201d in the lower left corner when the file upload is completed.<\/span><\/p>\n<p class=\"MsoBodyText\" style=\"margin: 0in 0in 6pt 0.5in; text-indent: -0.25in; tab-stops: list .5in; mso-list: l1 level1 lfo1;\"><span style=\"mso-fareast-font-family: Arial; mso-bidi-font-family: Arial;\"><span style=\"mso-list: Ignore;\"><span style=\"font-size: small; font-family: Arial;\">15.<\/span><span style=\"font: 7pt &amp;amp;amp;\"> <\/span><\/span><\/span><span style=\"font-size: small; font-family: Arial;\">Repeat steps 7 through 14 for any additional units.<\/span><\/p>\n<p class=\"MsoBodyText\" style=\"margin: 0in 0in 6pt;\">\u00a0<\/p>\n<h2 style=\"margin: 0in 0in 6pt;\"><em><span style=\"text-decoration: underline;\"><span style=\"font-size: small; font-family: Arial;\">2.0 Configuring the Modem<\/span><\/span><\/em><\/h2>\n<p class=\"MsoBodyText\" style=\"margin: 0in 0in 6pt 0.5in; text-indent: -0.25in; tab-stops: list .5in; mso-list: l0 level1 lfo2;\"><span style=\"mso-fareast-font-family: Arial; mso-bidi-font-family: Arial;\"><span style=\"mso-list: Ignore;\"><span style=\"font-size: small; font-family: Arial;\">1.<\/span><span style=\"font: 7pt &amp;amp;amp;\"> <\/span><\/span><\/span><span style=\"font-size: small; font-family: Arial;\">Close the Philips Flash Utility program.<\/span><\/p>\n<p class=\"MsoBodyText\" style=\"margin: 0in 0in 6pt 0.5in; text-indent: -0.25in; tab-stops: list .5in; mso-list: l0 level1 lfo2;\"><span style=\"mso-fareast-font-family: Arial; mso-bidi-font-family: Arial;\"><span style=\"mso-list: Ignore;\"><span style=\"font-size: small; font-family: Arial;\">2.<\/span><span style=\"font: 7pt &amp;amp;amp;\"> <\/span><\/span><\/span><span style=\"font-size: small; font-family: Arial;\">Open a terminal program with port settings of 8 data bits, no parity, 1 stop bit, and flow control off. The bps setting will depend on the previous modem configuration of the ATBD setting. For modem ID: 0001 and 0002 set the bps setting to 38400 and for modem ID: 0003 set the bps setting to 4800. <\/span><\/p>\n<p class=\"MsoBodyText\" style=\"margin: 0in 0in 6pt 0.5in; text-indent: -0.25in; tab-stops: list .5in; mso-list: l0 level1 lfo2;\"><span style=\"mso-fareast-font-family: Arial; mso-bidi-font-family: Arial;\"><span style=\"mso-list: Ignore;\"><span style=\"font-size: small; font-family: Arial;\">3.<\/span><span style=\"font: 7pt &amp;amp;amp;\"> <\/span><\/span><\/span><span style=\"font-size: small; font-family: Arial;\">Set a DC power supply for +12VDC.<\/span><\/p>\n<p class=\"MsoBodyText\" style=\"margin: 0in 0in 6pt 0.5in; text-indent: -0.25in; tab-stops: list .5in; mso-list: l0 level1 lfo2;\"><span style=\"mso-fareast-font-family: Arial; mso-bidi-font-family: Arial;\"><span style=\"mso-list: Ignore;\"><span style=\"font-size: small; font-family: Arial;\">4.<\/span><span style=\"font: 7pt &amp;amp;amp;\"> <\/span><\/span><\/span><span style=\"font-size: small; font-family: Arial;\">Connect the PC serial port to the modem\u2019s DB9 front panel connector.<\/span><\/p>\n<p class=\"MsoBodyText\" style=\"margin: 0in 0in 6pt 0.5in; text-indent: -0.25in; tab-stops: list .5in; mso-list: l0 level1 lfo2;\"><span style=\"mso-fareast-font-family: Arial; mso-bidi-font-family: Arial;\"><span style=\"mso-list: Ignore;\"><span style=\"font-size: small; font-family: Arial;\">5.<\/span><span style=\"font: 7pt &amp;amp;amp;\"> <\/span><\/span><\/span><span style=\"font-size: small; font-family: Arial;\">Connect the modem\u2019s green 2-pin power connector to the power supply. <\/span><\/p>\n<p class=\"MsoBodyText\" style=\"margin: 0in 0in 6pt 0.5in; text-indent: -0.25in; tab-stops: list .5in; mso-list: l0 level1 lfo2;\"><span style=\"mso-fareast-font-family: Arial; mso-bidi-font-family: Arial;\"><span style=\"mso-list: Ignore;\"><span style=\"font-size: small; font-family: Arial;\">6.<\/span><span style=\"font: 7pt &amp;amp;amp;\"> <\/span><\/span><\/span><span style=\"font-size: small; font-family: Arial;\">Type \u201c+++\u201d on the terminal program to enter the modem\u2019s configuration mode.<\/span><\/p>\n<p class=\"MsoBodyText\" style=\"margin: 0in 0in 6pt 0.5in; text-indent: -0.25in; tab-stops: list .5in; mso-list: l0 level1 lfo2;\"><span style=\"mso-fareast-font-family: Arial; mso-bidi-font-family: Arial;\"><span style=\"mso-list: Ignore;\"><span style=\"font-size: small; font-family: Arial;\">7.<\/span><span style=\"font: 7pt &amp;amp;amp;\"> <\/span><\/span><\/span><span style=\"font-size: small; font-family: Arial;\">Configure the product per the user manual and instructions in AN136. <\/span><\/p>\n<p class=\"MsoBodyText\" style=\"margin: 0in 0in 6pt 0.5in; text-indent: -0.25in; tab-stops: list .5in; mso-list: l0 level1 lfo2;\"><span style=\"font-size: small; font-family: Arial;\"><strong><em>3. Firmware Versions<\/em><\/strong><\/span><\/p>\n<p class=\"MsoBodyText\" style=\"margin: 0in 0in 6pt 0.5in; text-indent: -0.25in; tab-stops: list .5in; mso-list: l0 level1 lfo2;\"><span style=\"font-size: small; font-family: Arial;\">In most cases, the firmware in an M7 must be udated at the factory because updated radio modems should be completely re-calibrated and all parameters initialized.\u00a0 But, in certain cases it may be possible to perform the upgrade in the field.\u00a0 AN136 lists the parameters which must be re-calibrated or initialed when doing a firmware upgrade.\u00a0 <\/span><\/p>\n<p class=\"MsoBodyText\" style=\"margin: 0in 0in 6pt 0.5in; text-indent: -0.25in; tab-stops: list .5in; mso-list: l0 level1 lfo2;\"><span style=\"font-size: small; font-family: Arial;\">Below are links to firmware for the M7 data radio modem.\u00a0 <\/span><\/p>\n<p class=\"MsoBodyText\" style=\"margin: 0in 0in 6pt 0.5in; text-indent: -0.25in; tab-stops: list .5in; mso-list: l0 level1 lfo2;\"><a href=\"http:\/\/raveontech.com\/Firmware\/M7_DataRadio\/2F700C1.hex\"><span style=\"font-size: small; font-family: Arial;\">Revsion C1 hex file<\/span><\/a><\/p>\n<p class=\"MsoBodyText\" style=\"margin: 0in 0in 6pt 0.5in; text-indent: -0.25in; tab-stops: list .5in; mso-list: l0 level1 lfo2;\"><span style=\"font-size: small; font-family: Arial;\"><a href=\"http:\/\/raveontech.com\/Firmware\/M7_DataRadio\/2F700C1.zip\">Revision C1 zipped<\/a><\/span><\/p>\n<p><!--  \/* Style Definitions *\/  p.MsoNormal, li.MsoNormal, div.MsoNormal \t{mso-style-parent:\"\"; \tmargin-top:0in; \tmargin-right:0in; \tmargin-bottom:6.0pt; \tmargin-left:0in; \tmso-pagination:widow-orphan; \tfont-size:12.0pt; \tfont-family:Arial; \tmso-fareast-font-family:\"Times New Roman\"; \tmso-bidi-font-family:\"Times New Roman\"; \tmso-bidi-language:AR-SA;} p.MsoFooter, li.MsoFooter, div.MsoFooter \t{margin-top:0in; \tmargin-right:0in; \tmargin-bottom:6.0pt; \tmargin-left:0in; \tmso-pagination:widow-orphan; \ttab-stops:center 3.0in right 6.0in; \tfont-size:12.0pt; \tfont-family:Arial; \tmso-fareast-font-family:\"Times New Roman\"; \tmso-bidi-font-family:\"Times New Roman\"; \tmso-bidi-language:AR-SA;} @page Section1 \t{size:8.5in 11.0in; \tmargin:1.0in 63.0pt 1.0in 1.25in; \tmso-header-margin:.5in; \tmso-footer-margin:.5in; \tmso-paper-source:0;} div.Section1 \t{page:Section1;} --><!--[if gte mso 10]> <mce:style><!   \/* Style Definitions *\/  table.MsoNormalTable \t{mso-style-name:\"Table Normal\"; \tmso-tstyle-rowband-size:0; \tmso-tstyle-colband-size:0; \tmso-style-noshow:yes; \tmso-style-parent:\"\"; \tmso-padding-alt:0in 5.4pt 0in 5.4pt; \tmso-para-margin:0in; \tmso-para-margin-bottom:.0001pt; \tmso-pagination:widow-orphan; \tfont-size:10.0pt; \tfont-family:\"Times New Roman\"; \tmso-ansi-language:#0400; \tmso-fareast-language:#0400; \tmso-bidi-language:#0400;}  > <! [endif] ><\/div>\n\n\n\n\n<div class=\"MsoNormal\" mce_tmp=\"1\"><strong>ATCD -113<\/strong><span><span> <\/span>Set the carrier detect threshold to -113dBm. <\/span><\/div>\n\n\n\n\n<div class=\"MsoNormal\" style=\"margin: 0in 0in 6pt;\" mce_style=\"margin: 0in 0in 6pt;\" mce_tmp=\"1\"><span style=\"font-size: small; font-family: Arial;\" mce_style=\"font-size: small; font-family: Arial;\"> <\/span><\/div>\n\n\n\n\n<div id=\"_mcePaste\" style=\"overflow: hidden; position: absolute; left: -10000px; top: 1918px; width: 1px; height: 1px;\">\n\n\n<h2 style=\"margin: 0in 0in 6pt;\" mce_style=\"margin: 0in 0in 6pt;\"><em><span style=\"text-decoration: underline;\" mce_style=\"text-decoration: underline;\"><span style=\"font-size: small; font-family: Arial;\" mce_style=\"font-size: small; font-family: Arial;\">Re-calibrate RF power output calibration<\/span><\/span><\/em><\/h2>\n\n\n\n\n<div class=\"MsoNormal\" style=\"margin: 0in 0in 6pt 0.5in;\" mce_style=\"margin: 0in 0in 6pt 0.5in;\" mce_tmp=\"1\"><span style=\"font-family: Arial;\" mce_style=\"font-family: Arial;\"><strong><span style=\"font-size: small;\" mce_style=\"font-size: small;\">AT$P xx <\/span><\/strong><em><span style=\"font-size: 10pt;\" mce_style=\"font-size: 10pt;\">&lt;enter&gt;<span style=\"mso-spacerun: yes;\" mce_style=\"mso-spacerun: yes;\"> <\/span>adjust<span style=\"mso-spacerun: yes;\" mce_style=\"mso-spacerun: yes;\"> <\/span>XX value so that the RF power output is correct. Use a wattmeter connected to the M7 to read the power.<span style=\"mso-spacerun: yes;\" mce_style=\"mso-spacerun: yes;\"> <\/span>Monitor the current craw, and ensure it does not exceed 2.8A. <\/span><\/em><\/span><\/div>\n\n\n\n\n<div class=\"MsoNormal\" style=\"margin: 0in 0in 6pt 0.5in;\" mce_style=\"margin: 0in 0in 6pt 0.5in;\" mce_tmp=\"1\"><span style=\"font-family: Arial;\" mce_style=\"font-family: Arial;\"><strong><span style=\"font-size: small;\" mce_style=\"font-size: small;\">AT$R -10 <\/span><\/strong><em><span style=\"font-size: 10pt;\" mce_style=\"font-size: 10pt;\"><span style=\"mso-spacerun: yes;\" mce_style=\"mso-spacerun: yes;\"> <\/span>PA temperature compensation.<\/span><\/em><\/span><\/div>\n\n\n\n\n<div  mce_tmp=\"1\"><\/d ><\/d ><\/d--><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Overview This Technical Brief describes how to upload firmware into the RV-M7 transceiver. \u00a0The RV-M7 series transceivers utilize a Phillips ARM-based Microprocessor with internal FLASH memory. All RV-M7-GX series transceiver use an LPC2136 processor, which has 256kB of flash memory. Phillips Semiconductor provides a utility to upload firmware into the microprocessor. Their program is called [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[34],"tags":[],"_links":{"self":[{"href":"https:\/\/www.raveon.com\/data_radio_info\/wp-json\/wp\/v2\/posts\/65"}],"collection":[{"href":"https:\/\/www.raveon.com\/data_radio_info\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.raveon.com\/data_radio_info\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.raveon.com\/data_radio_info\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.raveon.com\/data_radio_info\/wp-json\/wp\/v2\/comments?post=65"}],"version-history":[{"count":4,"href":"https:\/\/www.raveon.com\/data_radio_info\/wp-json\/wp\/v2\/posts\/65\/revisions"}],"predecessor-version":[{"id":429,"href":"https:\/\/www.raveon.com\/data_radio_info\/wp-json\/wp\/v2\/posts\/65\/revisions\/429"}],"wp:attachment":[{"href":"https:\/\/www.raveon.com\/data_radio_info\/wp-json\/wp\/v2\/media?parent=65"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.raveon.com\/data_radio_info\/wp-json\/wp\/v2\/categories?post=65"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.raveon.com\/data_radio_info\/wp-json\/wp\/v2\/tags?post=65"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}